[zc] / Protocol.pm
1 package Protocol;
2 use warnings;
3 use strict;
4
5 require Exporter;
6
7 our @ISA = qw(Exporter);
8 our @EXPORT = qw( modbus_crc16 $protocol read_parameter_frame );
9
10 use Data::Dump qw(dump);
11
12 my $debug = $ENV{DEBUG} || 0;
13
14 # Table of CRC values for high order byte
15 use constant CRC_HI => [
16     0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1,
17     0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40,
18     0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1,
19     0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41,
20     0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1,
21     0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40,
22     0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1,
23     0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40,
24     0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0,
25     0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40,
26     0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0,
27     0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41,
28     0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1,
29     0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40,
30     0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0,
31     0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41,
32     0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0,
33     0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41,
34     0x00, 0xC1, 0x81, 0x40
35 ];
36  
37 # Table of CRC values for low order byte
38 use constant CRC_LO => [
39     0x00, 0xC0, 0xC1, 0x01, 0xC3, 0x03, 0x02, 0xC2, 0xC6, 0x06, 0x07, 0xC7, 0x05, 0xC5,
40     0xC4, 0x04, 0xCC, 0x0C, 0x0D, 0xCD, 0x0F, 0xCF, 0xCE, 0x0E, 0x0A, 0xCA, 0xCB, 0x0B,
41     0xC9, 0x09, 0x08, 0xC8, 0xD8, 0x18, 0x19, 0xD9, 0x1B, 0xDB, 0xDA, 0x1A, 0x1E, 0xDE,
42     0xDF, 0x1F, 0xDD, 0x1D, 0x1C, 0xDC, 0x14, 0xD4, 0xD5, 0x15, 0xD7, 0x17, 0x16, 0xD6,
43     0xD2, 0x12, 0x13, 0xD3, 0x11, 0xD1, 0xD0, 0x10, 0xF0, 0x30, 0x31, 0xF1, 0x33, 0xF3,
44     0xF2, 0x32, 0x36, 0xF6, 0xF7, 0x37, 0xF5, 0x35, 0x34, 0xF4, 0x3C, 0xFC, 0xFD, 0x3D,
45     0xFF, 0x3F, 0x3E, 0xFE, 0xFA, 0x3A, 0x3B, 0xFB, 0x39, 0xF9, 0xF8, 0x38, 0x28, 0xE8,
46     0xE9, 0x29, 0xEB, 0x2B, 0x2A, 0xEA, 0xEE, 0x2E, 0x2F, 0xEF, 0x2D, 0xED, 0xEC, 0x2C,
47     0xE4, 0x24, 0x25, 0xE5, 0x27, 0xE7, 0xE6, 0x26, 0x22, 0xE2, 0xE3, 0x23, 0xE1, 0x21,
48     0x20, 0xE0, 0xA0, 0x60, 0x61, 0xA1, 0x63, 0xA3, 0xA2, 0x62, 0x66, 0xA6, 0xA7, 0x67,
49     0xA5, 0x65, 0x64, 0xA4, 0x6C, 0xAC, 0xAD, 0x6D, 0xAF, 0x6F, 0x6E, 0xAE, 0xAA, 0x6A,
50     0x6B, 0xAB, 0x69, 0xA9, 0xA8, 0x68, 0x78, 0xB8, 0xB9, 0x79, 0xBB, 0x7B, 0x7A, 0xBA,
51     0xBE, 0x7E, 0x7F, 0xBF, 0x7D, 0xBD, 0xBC, 0x7C, 0xB4, 0x74, 0x75, 0xB5, 0x77, 0xB7,
52     0xB6, 0x76, 0x72, 0xB2, 0xB3, 0x73, 0xB1, 0x71, 0x70, 0xB0, 0x50, 0x90, 0x91, 0x51,
53     0x93, 0x53, 0x52, 0x92, 0x96, 0x56, 0x57, 0x97, 0x55, 0x95, 0x94, 0x54, 0x9C, 0x5C,
54     0x5D, 0x9D, 0x5F, 0x9F, 0x9E, 0x5E, 0x5A, 0x9A, 0x9B, 0x5B, 0x99, 0x59, 0x58, 0x98,
55     0x88, 0x48, 0x49, 0x89, 0x4B, 0x8B, 0x8A, 0x4A, 0x4E, 0x8E, 0x8F, 0x4F, 0x8D, 0x4D,
56     0x4C, 0x8C, 0x44, 0x84, 0x85, 0x45, 0x87, 0x47, 0x46, 0x86, 0x82, 0x42, 0x43, 0x83,
57     0x41, 0x81, 0x80, 0x40
58 ];
59
60 sub modbus_crc16 {
61         my ($msg) = @_;
62
63         my $crcl  = 0xFF;
64         my $crch  = 0xFF;
65         my @bytes = split(//, $msg);
66         for (@bytes) {
67                 my $data = unpack('C*', $_);
68                 my $crcIdx = $crcl ^ $data;
69                 $crcl = $crch ^ &CRC_HI->[$crcIdx];
70                 $crch = &CRC_LO->[$crcIdx];
71         }
72  
73         # Pack the trailer - CRC has low byte first
74         my $trlr = pack('CC', $crcl, $crch);
75
76         return $trlr;
77 }
78
79 our $protocol;
80 while(<DATA>) {
81         chomp;
82         next if m{^\s*$}; # skip empty lines
83         my @a = split(/\s*\t\s*/, $_,7);
84         my $id = hex( $a[0] );
85         my $pack_fmt = $a[2]; $pack_fmt =~ s/\s+.*$//;
86         $protocol->{$id} = {
87                 description => $a[1],
88                 pack_fmt => $pack_fmt,
89                 r_w => $a[3],
90                 range => $a[4],
91                 default => $a[5],
92                 remark => $a[6],
93                 line => [ @a ],
94         };
95 }
96
97 sub read_parameter_frame {
98         my $params = join('', @_);
99
100         my $frame
101                 = "\x5A" # header
102                 . "\x0B" # protocol version
103                 . "\x03" # function code
104                 . pack("v", length($params)) # data length
105         ;
106
107         $frame .= $params;
108
109         return $frame . modbus_crc16($frame);
110 }
111
112 1;
113
114 # 6. Protocol Format 
115 # Valid data ID and parameter range supported by the product 
116 # DATA ID       ID Description  Data Type( Data Length)       R/W     Range   Default         Remark 
117
118 __DATA__
119 0x00    Seq #                           l DWord(4)      R       /               0       The platform can carry the ID when the platform downstream reads and sets the device parameters, and the device returns the same data. Please refer to the example for use.Each seq # refer to one command and its response. 
120 0x01    PN                              l DWord(4)      R       /                /      / 
121 0x02    Model                           C Byte(1)       R       32              32      Inner number:32 
122 0x03    X axis angle                    f Float(4)      R        ‐90°~90°   /       X axis angle 
123 0x04    Y axis angle                    f Float(4)      R       ‐90°~90°    /       Y axis angle 
124 0x09    X axis relative angle           f Float(4)      R       ‐90°~90°    0       Return the X angle value according to the set relative zero 
125 0x0A    Y axis relative angle           f Float(4)      R       ‐90°~90°    0       Return the Y angle value according to the set relative zero 
126 0x0C    Sensor temperature              s Word(2)       R       ‐32768~32767  /       signed,sensor temperature =Data/100, unit ℃ 
127 0x0D    Power source voltage            S Word(2)       R       0~65535         /       Voltage= Data/100, unit V 
128 0x0E    Heartbeat interval              l DWord(4)      R/W     60~2160000      86400   ZCT330E Interval at which the device periodically uploads data to the server 
129 0x0F    Failure interval                l DWord(4)      R/W     60~2160000      3600    ZCT330E Interval at which the device failure is retransmitted
130 0x11    Arming/disarming                C Byte(1)       R/W     0~255           1       0 means disarming, non‐zero means arming 
131 0x12    Alarm delay time                C Byte(1)       R/W     3~255           20      ZCT330M The unit is 0.1 second, which means that the product responds to the alarm only after the alarm has exceeded the alarm angle for a certain period of time. (mot used by ZCT330E, only ZCT330M) 
132
133 0x13    Restore factory setting         C Byte(1)       R/W     0~255           0       0: Do nothing Non‐zero: Restore the non‐network‐related parameters of the sensor. 
134 0x14    Server IP&port                  CCCCs 4*Byte(1)+Word(2) R/W             /       CTIOT:117.60.157.137,5683 MQTT:0.0.0.0,0        The server address should be IP, not the domain name; using the domain name may cause the connection server to be unstable and cause data loss. After the function is set, content of 0x34 will be cleared, if 0x14 and 0x34 is set at the same time, priority is given to 0x14 (passive upload)
135 0x17    Signal strength                 C Byte(1)       R       10~34           /       A larger value indicates a stronger signal 
136 0x18    Sensor operating mode           C Byte(1)       R/W     0               0       0: absolute angle, 1: relative angle, 2: vibration, ZCT330Mx sensor can only work in absolute measurement mode, ZCT330Ex supports all modes
137 0x19    Alarm axis                      C Byte(1)       R       0~3             /       0: no alarm; 1: X‐axis alarm 2: Y axis alarm; 3: X/Y axis alarm at the same time 
138 0x1A    SIM card ID                     Q QWord(8)      R       0~18446744073709551615  /       Take the first 19 digits, the last digit is discarded 
139 0x1B    Alarm angle                     f Float(4)      R/W     0.06-30.00      5.0     ZCT330E relative mode, passive upload
140 0x1C    Alarm trigger time              l Dword(4)      R/W     2-20            2       ZCT330E relative mode, passive upload
141 0x1D    Static angle                    f Float(4)      R/W     0.06-30.00      2.5     ZCT330E relative mode, passive upload
142 0x1E    Static trigger time             l Dword(4)      R/W     2-20            2       ZCT330E relative mode, passive upload
143 0x1F    Acquisition interval            l Dword(4)      R/W     1-2160000       60      ZCT330E absolute mode, passive upload
144 0x20    Failure retransmission          l Dword(4)      R/W     20-2160000      3600    ZCT330E absolute mode, passive upload
145 0x21    Heartbeat interval              l DWord(4)      R/W     60~131071       86400   Interval at which the device periodically uploads data to the server 
146 0x22    IMEI number of the device       Q QWord(8)       R      0~18446744073709551615  /       Refers to the IMEI of the NB‐IOT network module in the product. 
147 0x23    Backup server IP&port           CCCCs 4*Byte(1)+Word(2) R/W     /       CTIOT:117.60.157.137,5683 MQTT:0.0.0.0,0        / if set, clears 0x3b, if 0x23 and 0x3b are set at same time, 0x23 has priority
148 0x24    Backup server enable            C Byte(1)       R/W     0~255   0       0 means off, non‐zero means on 
149 0x33    DNS IP address                  CCCC 4*Byte(1)  R/W     /       208.67.222.222  / 
150 0x34    Domain name and port            a* 64*Byte(1)   R/W     /       mqtt.zc‐sensor.com,1883       Supports CTIOT and MQTT protocols. Priority IP in the case of IP (ID number 0x14); domain name and port should be separated with comma, length <=64, cleared by setting 0x14
151 0x35    MQTT‐ClientID                         a* 32*Byte(1)   R/W      /      IMEI number of the device       Length <=32, subject to MQTT related specifications 
152 0x36    MQTT‐Username                         a* 32*Byte(1)   R/W     /       empty           Length <=32, subject to MQTT related specifications 
153
154 0x37    MQTT‐Password                         a* 32*Byte(1)   R/W     /       empty           Length <=32, subject to MQTT related specifications 
155 0x38    MQTT‐published topic name     a* 128*Byte(1)  R/W     /       Inclinometer/ZCT330Mx_SWP_N_YK/IMEI/up  Length <=128, subject to MQTT related specifications 
156 0x39    MQTT‐subscribed topic name    a* 128*Byte(1)  R/W     /       Inclinometer/ZCT330Mx_SWP_N_YK/IMEI/down        Length <=128, subject to MQTT related specifications 
157 0x3A    Set relative zero command       C Byte(1)       R/W     0~255   0               0: absolute angle mode 1: Set the current position to zero, relative angle mode (0x09, 0x0A content will be set to the current angle), Other values are invalid. 
158 0x3B    Backup server domain name and port      a* 64*Byte(1)   R/W     /       mqtt.zc‐sensor.com,1883       Supports CTIOT and MQTT protocols. In the case of backup IP, the IP is preferentially backed up; the domain name and port are distinguished by commas, and the length is <=64. , will be cleared if 0x23 is set
159 0x3D    Protocol type                   C Byte(1)       R/W     0~1     CTIOT   0:CTIOT 1:MQTT Other values are invalid. 
160 0x3E    Alarm angle                     f Float(4)      R/W     0.06-30.00      2.0     ZCT330E vibration mode, passive upload
161 0x3F    Alarm trigger time              l Dword(4)      R/W     80-20000        240     ZCT330E vibration mode, passive upload (trigger time in ms)
162 0x40    Static angle                    f Float(4)      R/W     0.06-30.00      1.0     ZCT330E vibration mode, passive upload
163 0x41    Static trigger time             l Dword(4)      R/W     80-20000        240     ZCT330E vibration mode, passive upload (trigger time in ms)
164 0x42    Heartbeat interval              l DWord(4)      R/W     60~2160000      86400   ZCT330E (unit: s) vibration mode, Interval at which the device periodically uploads data to the server 
165 0x43    Failure retransmission          l Dword(4)      R/W     20-2160000      3600    ZCT330E (unit: s) vibration mode, passive upload
166 0x44    Alarm angle                     f Float(4)      R/W     ZCT330M:‐90°~90°,ZCT330E:0.06-30.00         ZCT330M:3°,ZCT330E:5.0         X/Y axis alarm angle is consistent, ZCT330E in absolue mode, passsive upload 
167 0x45    Alarm trigger time              l Dword(4)      R/W     0-3600          0       ZCT330E Sensor waiting time for the server to issue a command (s), passive upload
168